Product Description
22kw Three Phase 32A Evse Controller with RFID for EV Charging Station
OVERVIEW OF THE CONTROLLER
E32T21 FEATURES The controller is a DIN rail mounted control module for IEC 61851 compatible EV charge points.
Key features include RCM and DLB, helping charge station manufacturers and installers meet regulations in a cost-effective way and protect against electric shock in the unlikely event of an earth fault problem.
SEQUENCE OF CHARGING PROCESS
INITIALIZATION After the operating voltage is applied, the module carries out initializations and function tests indicated and then waits for vehicle connection (indicated by pulsing blue LED). Tethered version:indicated by pulsing blue LED Socket outlets version:indicated by steady blue LED CHARGING PROCESS The module waits for a charging cable or vehicle to be connected (state A) indicated . If an approved connecting cable has been connected and state B is indicated by the vehicle. Tethered version:indicated by steady blue LED Socket outlets version:indicated by pulsing blue LED
After interlocking, the charge-enable relays are activated if the vehicle is signalling state C. The charging process is activated, and the LED is changed to steady-green( Tethered version)or pulsing[1]green(Socket outlets version). If state D is indicated (ventilation required) then charging and interlock are deactivated as the E32T21 does not provide a fan-enable mechanism, and the LED is changed to steady-red .
Technical Data |
|
Model: |
AG-E32T21 |
Pole No.: |
1P+N, 3P+N |
Rated current(A): |
25, 32, 40, 63A |
Rated working voltage(I n): |
30, 100, 300, 500mA |
Rated voltage(V): |
AC 230(240)/400(415) |
Rated frequency(Hz): |
50/60 |
Rated making and breaking capacity: |
500(In=25A,32,40A), 630(In=63A) |
Rated conditional short-circuit current Inc: |
6kA |
Rated conditional residual short-circuit Current I c: |
6kA |
Rated residual non operating current I no: |
0.5I n |
Residual operating current range: |
0.5I n~I n |
Operating time: |
≤0.3s |
Type: |
A and AC type |
Rated short-circuit breaking capacity: |
6KA |
Mechanical life: |
Not less than 4000 times |
Degree of protection: |
IP20 |
Products name: |
3 pole rccb circuit breaker |